Search results for "Threshold limit value"
showing 10 items of 23 documents
Long-term modelling of weed control strategies: analysis of threshold-based options for weed species with contrasted competitive abilities
2002
A simple life-cycle-based demography model was adapted for two contrasting weed species (Alopecurus myosuroides and Poa annual. This model included a seed production function that accounted for population self-regulation through weed:weed interactions. The A. myosuroides version of the model was tested with field data. Long-term simulations of population demography were then performed to investigate the relationship between weed control strategies based on density thresholds and both the frequency of herbicide use and the long-term economic profitability. This study confirms that threshold-based weed management strategies are more cost-effective than spraying every year and may allow import…
Acute effects on the human EEG after an external exposure to 200 ppm methanol
2001
Objectives: Even low concentrations of organic solvents may cause acute effects on the human central nervous system. The German MAK (threshold limit value) of methanol is 200 ppm. The aim of this study was to investigate whether acute exposure to 200 ppm methanol causes adverse effects, measured by EEG, and moreover, whether it is possible to differentiate between sedative and excitatory effects with this method. Methods: Twelve healthy subjects were exposed for 4 h to 200 ppm and to 20 ppm (control) in an exposure chamber in a cross-over design. The EEG was recorded before (reference) and at the end of each exposure with, the subject's eyes closed and opened and during a choice reaction te…
Mechanical–biological waste treatment and the associated occupational hygiene in Finland
2004
A special feature of waste management in Finland has been the emphasis on the source separation of kitchen biowaste (catering waste); more than two-thirds of the Finnish population participates in this separation. Source-separated biowaste is usually treated by composting. The biowaste of about 5% of the population is handled by mechanical-biological treatment. A waste treatment plant at Mustasaari is the only plant in Finland using digestion for kitchen biowaste. For the protection of their employees, the plant owners commissioned a study on environmental factors and occupational hygiene in the plant area. During 1998-2000 the concentrations of dust, microbes and endotoxins and noise level…
Occupational exposure to metal-rich particulate matter modifies the expression of repair genes in foundry workers
2021
Foundry workers are exposed to numerous occupational health hazards, which may result in increased risk of cancer, respiratory disease, and other diseases. Oxidative stress is known to be involved in the pathogenesis of such diseases. The present study aimed to investigate the association between multiple occupational exposures in foundry workers and expression of deoxyribonucleic acid (DNA) repair genes as a biomarker of oxidative DNA damage. The study sample comprised 17 foundry workers and 27 matched control subjects. Expression of 8-oxoguanine DNA glycosylase-1 (OGG1), inosine triphosphate pyrophosphate (ITPA), and MutT homolog 1 (MTH1) in peripheral blood was examined using the real-t…
Effects on Heat Stress of a Flame-Retardant Ensemble for Aluminum Smelters
2000
A common belief is that a flame-retardant clothing ensemble will increase the level of heat stress over ordinary cotton work clothes. This is supported by bench tests on fabrics that indicate higher insulation and vapor resistance values for flame-retardant clothing. This research compared a flame-retardant clothing ensemble for an aluminum smelter (Zirpo wool shirt and FR8 denim pants) with typical cotton work clothing. Four young men walked on a treadmill at two work levels inside a climatic chamber under controlled conditions of heat stress. During each test, heart rate, core temperature, and skin temperatures were continuously monitored and recorded every 5 min. After a physiological st…
External and internal exposure to polycyclic aromatic hydrocarbons (PAH) among workers in the production of fire-proof materials – Proposal of a biol…
2006
In 1999, we introduced the German polycyclic aromatic hydrocarbons (PAH) study. The study was designed as a nation-wide investigation on workers exposed to PAH. One aim of the study was to establish biological monitoring guidance values (BMGVs) for different branches. Here, we report on the production of fire-proof materials. This branch of industry is typically confronted with high exposure to PAH and with PAH-induced occupational (cancer) diseases. One hundred and thirty-five employees participated in the course of seven sampling dates in four different plants in Germany. External exposure was determined by personal air monitoring of the 16 EPA-PAH. Human biological monitoring was accompl…
Investigating the level of significance of the coherence function in cardiovascular variability analysis
2002
Although the presence of significant coupling between cardiovascular variability series is usually verified according to the threshold value of 0.5 in the coherence function (CF), spectral estimator parameters should also be considered. In this study, the surrogate data technique was introduced to define the level of significance of the CF. The proposed method determined a frequency-dependent threshold over which the hypothesis of zero coherence was rejected. The weighted covariance method and the autoregressive method were used to estimate the CF on simulated series with different degrees of linear coupling and on real cardiovascular data. The threshold was dependent on the type and parame…
Indoor air quality in schools of a highly polluted south Mediterranean area
2019
This study aimed at surveying lower secondary schools in southern Italy, in a highly polluted area. A community close to an industrial area and three villages in rural areas was investigated. Indoor temperature, relative humidity (RH), gaseous pollutants (CO 2 and NO 2 ), selected biological pollutants in indoor dust, and the indoor/outdoor mass concentration and elemental composition of PM 2.5 were ascertained. Temperature and RH were within, or close to, the comfort range, while CO 2 frequently exceeded the threshold of 1000 ppm, indicating inadequate air exchange rate. In all the classrooms, median NO 2 levels were above the WHO threshold value. Dermatophagoides p. allergen concentration…
A criterion for the assessment of the reliability of ASHRAE conduction transfer function coefficients
2010
This paper presents a new mathematical approach, which, when applied to conduction transfer functions (CTFs) of a multi-layered wall, is able to predict the reliability of building simulations. This new procedure can be used to identify the best set of CTF coefficients, which are a critical point at the core of the ASHRAE calculation methodology founded on the transfer function method. To evaluate the performance of different CTF coefficient sets, the authors performed a large number of thermal simulations on the multi-layered walls included in the ASHRAE Handbook, volume fundamentals, and on other walls typical of Mediterranean building heritage. Those data were employed to test an algorit…
Occupational hygiene in a waste incineration plant
2003
Abstract The Turku incineration plant was renovated in 1995 to meet the emission requirements of modern waste combustion facilities. It treats presorted municipal waste from 170,000 residents in the Turku area. In the plant, the incineration process produces several types of by-products having importance in terms of occupational hygiene. Although not obligated by the law, the management of the plant has a keen interest in occupational hygiene at the plant, which was studied from 1998 to 2001. Concentrations of microbes, endotoxins, and dust and the noise level were investigated in three different working areas. Microbe measurements were conducted with a six-stage impactor and using the CAMN…